L-type of Inter-Connector

The L-type of Inter-Connectors are used for connecting PCB's to tracks on LCD's that are on the same side as the viewing side of the LCD; on the top of the glass. L-type of Inter-Connectors are particularly suitable for connecting PCB's to dot-matrix LCD's.

All L-type of Inter-Connectors are custom made to order using specially designed tools. The dimensions given below are for a typical shape.
Alternative Inter-Connector for the tracks on the top of the glass is the JS-type.

Outline Dimensions and application
   
 L-type  Dot-matrix LCD

  

Dimensions and Tolerances
   

 Unit

 0.05P  0.10P  0.18P  0.25P
 Pitch  P  mm  0.05 +0.03/-0.01  0.10±0.05  0.18±0.05  0.25± 005
 Length  L  mm  5.0 ~ 90.0 ± 0.65%
 90.1 ~ 150.0 ± 0.6
 150.1 ~ 200.0 ± 1.0
 200.1 ~ 275.0 ± 1.5
 Height  H
 H1 (H≤8.0)
 H1 (H≥8.0)
 H2
 H3
 mm  4.1 ~ 10.0 ± 0.2     10.1 ~ 15.5 ± 0.6
1.5 ~ 5.2 ± 0.2
 ≥ 5.3 ± 0.25
 0.7 / 1.1 / 1.2 - typical 1.1
1.1 ~ 5.0 ± 0.1 - typical 1.7
 Width  W
 W1
 W2
 mm  3.0 ~ 6.0 ± 0.2 - preferable 4.0   
 ≥ 1.0 ± 0.2
1.0 ~ 3.0 ± 0.15
 Width conductive core  Z  mm  0.7 ± 0.05  0.5 ± 0.05

 

Basic Properties
     Unit  0.05P  0.10P/0.18P/0.25P
 Specific gravity  Isolator
 Conductor
 Side isolation
   1.15
 1.15
 1.05
 Shore hardness A  Isolator
 Conductor
 Side isolation
 ISO7619A  65 ~ 73
 60 ~ 65
 40 ~ 50
 65 ~ 73
 63 ~ 67
 40 ~ 50
 Compression set *    % 15 ~ 20
 Volume resistance  Isolator
 Conductor
 Side isolation
 Ω.cm  1.0 • 1014
 0.7 ~ 1.0
 1.0 • 1014
 1.0 • 1014
 3.0 ~ 6.0
 0.8 • 1014
 Dielectric breakdown voltage  Isolator
 Side isolation
 kV/mm  23 ~ 27
 23 ~ 27
 Isolation resistance (500V DC) *    MΩ  > 1.0 • 103
 Operating temperature range    °C  -25 ~ 85

* Tests carried out with Shin-Etsu standard methods.

Note:
Shin-Etsu Inter-Connector has been registered in the European Community, TM No. 000299016, and in the United States of America, TM No. 2078941.
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
Compression curves are for reference only. Actual resistances and compression forces are up to the design of substrates and holder constructions.
More information can be found in the design guides.
The quality of the assembled Inter-Connector is out of guarantee.
Please make sure to review the purpose and conditions of use and practice your own tests.
Industrial ownership like patent doesn't guarantee the usage of the Inter-Connector.